Promise Technology E610s Handbuch Seite 264

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 434
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 263
VTrak E-Class Product Manual
246
6. Close your SSH session.
7. Wait about two minutes.
8. Re-establish your SSH connection to the VTrak CLU.
See “Making a SSH Connection” on page 167.
If you cannot re-establish a connection, wait 30 seconds and try again.
Restarting VTrak – Serial Connection
To restart the RAID subsystem:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Highlight Option and press the spacebar to display Restart.
4. Highlight Submit and press Enter.
A warning message appears.
5. Press Y to continue.
The screen displays shutdown and startup functions.
6. When the Login: prompt appears, log into the CLU again.
Seitenansicht 263
1 2 ... 259 260 261 262 263 264 265 266 267 268 269 ... 433 434

Kommentare zu diesen Handbüchern

Keine Kommentare