SuperTrak EX Series User Manual
208
temppollint=Drive temperature polling interval in seconds. If value is 0,
polling is disabled. For subsystems with dual controllers.
15..255
mediumerrorthreshold=
Medium error threshold. If the threshold is reached, the
physical drive is marked as dead. The default value is 0,
indicating that physical drive is not marked as dead for
medium errors. For subsystems with dual controllers.
0..4294967294
The following settings are only for SATA drives:
dmamode= For SATA drive only. Attempt to negotiate at the specified
DMA transfer mode. If a DMA transer mode cannot be
negotiate, the next slower mode is attempted until a
mode can be negotiated (udma5, udma4....udma0,
mdma 2.....mdma0).
udma0 Ultra DMA Mode 0
udma1 Ultra DMA Mode 1
udma2 Ultra DMA Mode 2
udma3 Ultra DMA Mode 3
udma4 Ultra DMA Mode 4
udma5 Ultra DMA Mode 5
mdma0 Multi DMA Mode 0
mdma1 Multi DMA Mode 1
mdma2 Multi DMA Mode 2
speed= Set the speed of physical drive(s).
1.5gb 1.5 GB/s
3gb 3 GB/s
auto Automatic
The following settings are only for SAS drives:
readcache= Applied to SAS drive only. Enables or disables read
cache on the physical drive(s).
enable
disable
-v Verbose mode. Used with -a list.
Examples
phydrv
phydrv -v