Promise Technology VessRAID 1000s Series Handbuch Seite 272

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 340
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 271
VessRAID 1000s Series Product Manual
256
RAID 10
A RAID 10 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 5 3 physical drives minimum, 32 maximum.
RAID 10 must have less than 16 physical drives.
RAID 6 4 physical drives minimum, 32maximum.
RAID 10 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Add physical drives.
Even number of physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.