Promise-technology VTrack M-Class M200i Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Promise-technology VTrack M-Class M200i herunter. Promise Technology VTrack M-Class M200i User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 322
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - M200f, M200i, M200p

VTRAKM-CLASSM500f, M500i, M500p, M300f, M300i, M300p, M200f, M200i, M200pPRODUCT MANUALVersion 1.5 / SR-3

Seite 2 - Recommendations

VTrak M-Class Product Manual2OverviewVTrak provides data storage solutions for applications where high performance and data protection are required. T

Seite 3 - Contents

VTrak M-Class Product Manual92iSCSI iSNSThe iSCSI Management–iSNS tab enables you to view and change the current iSNS settings on the Controller data

Seite 4

Chapter 4: Management with WebPAM PROe93iSCSI SLPThe iSCSI Management–SLP tab enables you to view and change the current settings on the Controller da

Seite 5

VTrak M-Class Product Manual942. Click the Administrative Tools icon. 3. Click on the iSCSI Management icon. 4. Click on the CHAP tab in Managemen

Seite 6

Chapter 4: Management with WebPAM PROe953. Click on the iSCSI Management icon. 4. Click on the CHAP tab in Management View. 5. Click on the CHAP tab

Seite 7

VTrak M-Class Product Manual964. Click on the Channel 1 or the Channel 2 link.The settings screen displays a list of the 16 Targets and Termination fo

Seite 8

Chapter 4: Management with WebPAM PROe97Storage ServicesStorage Services include managing Initiator and LUN mapping. These functions are similar for F

Seite 9

VTrak M-Class Product Manual98LUN Map – Fibre Channel and iSCSIThe Storage Services–LUN Map tab displays a list of initiators recognized by the VTrak

Seite 10 - Overview

Chapter 4: Management with WebPAM PROe99LUN Mapping Parameters• Initiator – The Fibre Channel or iSCSI card in the Host system that initiates commands

Seite 11 - Controller

VTrak M-Class Product Manual1004. Click the LUN Map tab in Management View. 5. From the LUN Map tab dropdown menu, select Edit LUN Map. 6. Select Port

Seite 12 - Features and Benefits

Chapter 4: Management with WebPAM PROe1018. Enter an Email sender address (example: [email protected]). 9. Enter an Email subject (example: VTrak

Seite 13 - Chapter 1: Introduction

Chapter 1: Introduction3Figure 3. VTrak M500f Rear View (M500i/p have different controllers) Figure 4. VTrak M300i/M200i Rear View (M300f/M200f and M3

Seite 14 - Specifications

VTrak M-Class Product Manual1023. Click on the SLP Setting link. 4. Under Startup Type: • Click on the Automatic option to start the service automatic

Seite 15

Chapter 4: Management with WebPAM PROe10311. Click OK in the confirmation box to restart the Web Server service with your changes. Change Start Settin

Seite 16 - M300f/i/p, M200f/i/p

VTrak M-Class Product Manual10424 minutes is the default. 7. When you are done, click on the Submit button. 8. Click OK in the confirmation box to res

Seite 17 - FCC Statement

Chapter 4: Management with WebPAM PROe105There is no default name. 6. Enter a System Location.USA is the default. 7. Enter a System Contact (the email

Seite 18

VTrak M-Class Product Manual106Or click on the Restart button to restart the service. CIMVTrak’s CIM service provides a database for information about

Seite 19 - Chapter 2: Installation

Chapter 4: Management with WebPAM PROe1075. To enable CIM using a HTTPS connection: • Choose the Yes option • Enter a port number in the field provide

Seite 20 - VTrak M500f

VTrak M-Class Product Manual1082. Click on the Administration Tools icon. 3. Click on the Netsend link. 4. Under Startup Type: • Click on the Automa

Seite 21

Chapter 4: Management with WebPAM PROe109ExportThe Software Management–Export tab enables you to export the User Database file from the VTrak subsyste

Seite 22

VTrak M-Class Product Manual1104. Click on the Import tab. 5. Under the Type dropdown list, select User Database. 6. Enter the name of the file to be

Seite 23

Chapter 4: Management with WebPAM PROe1114. Check the Firmware and Software functions you want to restore to default settings. 5. Click on the Submit

Seite 24 - Install Disk Drives

VTrak M-Class Product Manual4All M-Class enclosures include a mid-plane, RAID controller, power and cooling units; and enclosure processor all in one

Seite 25 - Counter-sink screws only

VTrak M-Class Product Manual112When the controller shuts down, your WebPAM PROe connection will be lost. 8. Wait for no less than two minutes. 9. Manu

Seite 26 - Drive Numbering

Chapter 4: Management with WebPAM PROe113ControllersThe Controllers–Information tab provides information about the controllers in a VTrak subsystem. C

Seite 27

VTrak M-Class Product Manual114The Controller Status LED and Dirty Cache LED on the back of the Controller, will flash for one minute. See the ill

Seite 28 - FC 1 FC 2

Chapter 4: Management with WebPAM PROe115• Model • Status •Power On Time • Cache Usage (percent) • Dirty Cache Usage (percent) • Part number • Serial

Seite 29

VTrak M-Class Product Manual116• Write Back Cache Flush IntervalController Statistics1. Click the Subsystem icon in Tree View. 2. Click the Controll

Seite 30

Chapter 4: Management with WebPAM PROe1176. Check the SMART Log box to enable the Self-Monitoring, Analysis, and Reporting System (SMART). 7. Enter a

Seite 31

VTrak M-Class Product Manual118• Number of batteries – One for each controller in the enclosure Identify EnclosureTo identify the VTrak subsystem encl

Seite 32 - SCSI Direct Attached Storage

Chapter 4: Management with WebPAM PROe119EnclosureEnclosure InformationThe Enclosure–Information tab provides a diagram showing the status and locatio

Seite 33

VTrak M-Class Product Manual12010. Click the Submit button.The changes take effect immediately. FRU VPDThe Enclosure–FRU VPD tab displays Vital Produc

Seite 34 - Connect the Power

Chapter 4: Management with WebPAM PROe121• Current – A flow of a few mA is normal Battery ReconditionVTrak automatically reconditions the battery ever

Seite 35

Chapter 1: Introduction5Hardware-assisted XOR engine High-speed parity calculation for parity type logical drives.Supports out-of-band management thro

Seite 36

VTrak M-Class Product Manual1227. Click the Submit button.The Buzzer goes silent for the current event. If the Buzzer is enabled, it will sound again

Seite 37 - Chapter 3: Setup

Chapter 4: Management with WebPAM PROe123The Disk Status LED will flash to identify the carrier holding the drive.Figure 9. VTrak M500f/i/p disk carri

Seite 38 - M200f/p)

VTrak M-Class Product Manual124Physical DriveThe Physical Drive–Information tab provides information about the selected physical disk drive:Physical D

Seite 39

Chapter 4: Management with WebPAM PROe125• Maximum Ultra DMA Mode Supported – UDMA5 for SATA drives. • Ultra DMA Mode – Mode as selected on the Physic

Seite 40

VTrak M-Class Product Manual126The Disk Status LED will flash to identify the carrier holding the drive.Figure 11.VTrak M500f/i/p disk carrier LEDsFig

Seite 41 - Management Port

Chapter 4: Management with WebPAM PROe127• PFA – The physical drive has errors resulting in a prediction of failure. To clear a Stale or PFA status fr

Seite 42

VTrak M-Class Product Manual1284. Click on the Physical Drives icon. 5. Click on a Physical Drive icon. 6. Click on the Force Offline/Online tab i

Seite 43

Chapter 4: Management with WebPAM PROe129To access the Disk Arrays–Information tab:1. Click the Subsystem icon in Tree View. 2. Click on the Disk Ar

Seite 44

VTrak M-Class Product Manual130To create a new disk array:1. Click the Subsystem icon in Tree View. 2. Click on the Disk Arrays icon. 3. Click on

Seite 45

Chapter 4: Management with WebPAM PROe131Create a Disk Array – AdvancedThe Disk Array Advanced Creation option enables you to directly specify all par

Seite 46

VTrak M-Class Product Manual6SpecificationsM500f/i/pDrive Capacity: 15 SATA disk drives (3.5" x 1" form factor only).External I/O Ports (M50

Seite 47

VTrak M-Class Product Manual132This value will be the data capacity of the first logical drive in your new disk array. If you specify less than disk a

Seite 48

Chapter 4: Management with WebPAM PROe1332. Click on the Disk Arrays icon. 3. Click on the Delete tab in Management View. 4. Check the box to the le

Seite 49 - VTrak Setup with WebPAM PROe

VTrak M-Class Product Manual134• Number of Logical Drives – The number of logical drives that belong to this disk array. • Supported RAID Level – The

Seite 50

Chapter 4: Management with WebPAM PROe135• Transport Ready – After you perform a successful Prepare for Transport operation, this condition means you

Seite 51

VTrak M-Class Product Manual1361. Click the Subsystem icon in Tree View. 2. Click on the Disk Arrays icon. 3. Click on the Disk Array icon. 4. C

Seite 52 - Language Selection

Chapter 4: Management with WebPAM PROe137If you created a fault-tolerant logical drive (any RAID level except RAID 0), the Operational Status of new l

Seite 53 - Create a Disk Array

VTrak M-Class Product Manual138For a list of Migration options and other important information, see “RAID Level Migration” on page 254.To Migrate an e

Seite 54

Chapter 4: Management with WebPAM PROe139Manual RebuildIf a physical drive has failed, identify and replace the drive, then rebuild the disk array as

Seite 55

VTrak M-Class Product Manual1405. From the dropdown menu on the Background Activities tab, choose the function you want to start. View Progress of Bac

Seite 56

Chapter 4: Management with WebPAM PROe141TransportThe Disk Array–Transport tab enables you to prepare a disk array for transport. To prepare a disk ar

Seite 57

Chapter 1: Introduction7Any combination of these RAID levels can exist at once on separate logical drives. See page 239 for more information on RAID.R

Seite 58

VTrak M-Class Product Manual142• RAID Level – The RAID level of this logical drive (It may differ from the disk array). • Capacity – This is the data

Seite 59

Chapter 4: Management with WebPAM PROe143• Offline – This condition arises as the result of a second physical drive failure. An Offline logical drive

Seite 60

VTrak M-Class Product Manual144• Read Policy – The Read Cache policy of this logical drive. • Write Policy – The Write Cache policy of this logical dr

Seite 61

Chapter 4: Management with WebPAM PROe145Maximum of 32 characters. Use letters, numbers, space between words, and underscore. An alias is optional.8.

Seite 62 - Log-out of WebPAM PROe

VTrak M-Class Product Manual1467. If you did not select Quick Initialization, enter a hexidecimal value in the Initialization Pattern in Hex field or

Seite 63

Chapter 4: Management with WebPAM PROe147Logical Drive PDMPredictive Data Migration (PDM) is the migration of data from the suspect disk drive to a sp

Seite 64

VTrak M-Class Product Manual148• Count – Number of continuous blocks starting from this LBA. • Read Check Table – Contains a list of read errors for t

Seite 65

Chapter 4: Management with WebPAM PROe149 LUN Mapping Parameters• Initiator Name – For iSCSI, the initiator name is the iSCSI name of the initiator de

Seite 66

VTrak M-Class Product Manual1507. From the Assigned Channel List, click on Channel 1 or 2.The Channel ID number appears under LUN Assignment Worksheet

Seite 67

Chapter 4: Management with WebPAM PROe151• Type – Global, can be used by any disk array. Dedicated, can only be used by the assigned disk array. • Ded

Seite 68

VTrak M-Class Product Manual8Safety Certifications: CE, FCC Class A, BSMI, VCCi, cUL, TUV, MICLimited Warranty: 3 Years (See page 302 for details)M300

Seite 69 - Log-in/Log-out

VTrak M-Class Product Manual152The new spare drive is added to the Spare Drive List on the Information tab. Delete Spare DriveThe Spare Drives–Delete

Seite 70 - 4. Click the Login button

Chapter 4: Management with WebPAM PROe153Spare DriveSpare Drive InformationWhen a physical drive in a disk array fails and a spare drive of adequate c

Seite 71

VTrak M-Class Product Manual154The Disk Status LED will flash to identify the carrier holding the drive.Figure 13.VTrak M500f/i/p disk carrier LEDsFig

Seite 72 - Graphic User Interface

Chapter 4: Management with WebPAM PROe1559. Click on the Submit button.The new spare drive settings are shown in the Spare Drive List on the Informati

Seite 73 - Item Function

VTrak M-Class Product Manual156

Seite 74 - Contact Us

157Chapter 5: Management with the CLUVTrak Status IndicatorsEven though the Command Line Utility (CLU) offers comprehensive monitoring of VTrak, the L

Seite 75 - Tree View

VTrak M-Class Product Manual158Figure 2. VTrak M300f/i/p and M200f/i/p front panel LED displayWhen boot-up is finished and the VTrak is functioning no

Seite 76 - Subsystems

Chapter 5: Management with the CLU159See page 215 for more information about field-replaceable components. See page 286 for a discussion of critical a

Seite 77 - Subsystem

VTrak M-Class Product Manual160Figure 4. VTrak M300f/i/p and M200f/i/p disk carrier LEDsThe VTrak spins up the disk drives sequentially in order to eq

Seite 78 - Subsystem Events

Chapter 5: Management with the CLU161The audible alarm sounds at other times to inform you that the VTrak needs attention. But the alarm does not spec

Seite 79 - Background Activities

Chapter 1: Introduction9Supported Operating Systems: Current: 8 A @ 100 VAC; 4 A @ 200 VAC (max. rating with two power cords)Power Consumption: 340 wa

Seite 80 - Scheduler

VTrak M-Class Product Manual162The default user name is administrator. 3. At the Password prompt, type the password and press Enter. The default passw

Seite 81

Chapter 5: Management with the CLU163Logical Drive Management – View logical drive information, name logical drives, initialization and redundancy che

Seite 82

VTrak M-Class Product Manual164CLU Function MapThe map below is designed to help you navigate to the submenu where each function is located. Begin at

Seite 83 - Administrative Tools

Chapter 5: Management with the CLU165C, continuedCIM, settings – Main Menu, Additional Info and Management, Software Management, CIMClear Events, runt

Seite 84 - User Settings – User

VTrak M-Class Product Manual166E, continuedEnclosure, temperature – Main Menu, Subsystem Management, Enclosure Management, Temperature SensorsEnclosur

Seite 85 - User Event Subscription

Chapter 5: Management with the CLU167I, continuedInitiator, create/delete – Main Menu, Additional Info and Management, LUN MappingInitiators, Fibre Ch

Seite 86

VTrak M-Class Product Manual168L, continuedLogical Drive, locate – Main Menu, Logical Drive Management, individual logical driveLogical Drive, read ca

Seite 87 - Create a User

Chapter 5: Management with the CLU169P, continuedPFA Condition, clear – Main Menu, Physical Drive Management, individual Physical DrivePhysical Drives

Seite 88 - Delete a User

VTrak M-Class Product Manual170SSessions, iSCSI – Main Menu, iSCSI Management, iSCSI SessionsSettings, restore defaults – Main Menu, Additional Info a

Seite 89

Chapter 5: Management with the CLU171S, continuedStatistics, logical drive – Main Menu, Logical Drive Management, individual logical driveStatistics,

Seite 90

VTrak M-Class Product Manual10

Seite 91

VTrak M-Class Product Manual172U, continuedUser, privilege – Main Menu, Additional Info and Management, User Management, user from listUser, settings

Seite 92 - Fibre Channel Port Settings

Chapter 5: Management with the CLU173Quick SetupQuick Setup is discussed under “VTrak Setup with CLI or CLU” on page 29.Subsystem ManagementSubsystem

Seite 93 - Fibre Channel Statistics

VTrak M-Class Product Manual1741440 minutes = 24 hours2. Highlight Lock and press Enter.To reset the lock with a new time:1. In the Lock Time field, t

Seite 94 - Fibre Channel SFP

Chapter 5: Management with the CLU1752. Highlight Controller Management and press Enter.3. Highlight the controller you want and press Enter.4. Highli

Seite 95

VTrak M-Class Product Manual1764. Press Ctrl-A to save your settings.Enclosure ManagementEnclosure Management includes information, status, settings a

Seite 96

Chapter 5: Management with the CLU177If either blower speed is below the Healthy Threshold, there is a blower malfunction. See “Chapter 6: Maintenance

Seite 97

VTrak M-Class Product Manual1783. Press Ctrl-A to save your settings.Temperature ThresholdsTemperature thresholds are the temperature levels the Contr

Seite 98

Chapter 5: Management with the CLU179• Battery Current – Positive during charge, negative during dischargeTo recondition the battery:1. Highlight Reco

Seite 99

VTrak M-Class Product Manual1801. Highlight DMA Mode and press the spacebar to toggle through UDMA 0 – 5 and MDMA 0 – 2.2. Press Ctrl-A to save your s

Seite 100 - VTrak M-Class Product Manual

Chapter 5: Management with the CLU181If a physical drive is offline and shows a PFA error, rebuild the disk array. Go to Disk Array Info and Settings.

Seite 101

11Chapter 2: Installation• Unpack the VTrak storage subsystem (below)• Mount VTrak M500f/i/p in a Rack (page 12)• Mount VTrak M300f/i/p or M200f/i/p i

Seite 102

VTrak M-Class Product Manual182Disk Array ManagementDisk Array Management includes the creation and deletion of disk arrays, disk array settings and f

Seite 103 - SCSI Management

Chapter 5: Management with the CLU1832. Highlight Number of Logical Drives and press the backspace key to erase the current value.3. Enter the number

Seite 104 - SCSI Target Information

VTrak M-Class Product Manual1847. Highlight RAID Level and press the spacebar to toggle though a list of available RAID levels.8. If you want to creat

Seite 105 - Storage Services

Chapter 5: Management with the CLU185Disk Array Information1. From the Main Menu, highlight Disk Array Management and press Enter.2. Highlight the dis

Seite 106

VTrak M-Class Product Manual1862. Specify the source and target physical drives.3. Highlight Start and press Enter.MigrationThis function includes RAI

Seite 107 - LUN Map – SCSI

Chapter 5: Management with the CLU187TransitionTransition is the process of replacing a revertible spare drive that is currently part of a disk array

Seite 108 - Software Management

VTrak M-Class Product Manual1884. Highlight the following parameters and press the backspace key to erase the current value:• Alias - Type an alias in

Seite 109

Chapter 5: Management with the CLU189Logical Drive Information1. From the Main Menu, highlight Logical Drive Management and press Enter.2. Highlight t

Seite 110 - Web Server

VTrak M-Class Product Manual190The initialization parameters appear.• Initialization pattern. The default 00000000 is best for most applications• Quic

Seite 111

Chapter 5: Management with the CLU191Network ManagementNetwork Management deals with network connections and settings for VTrak’s Management Port and,

Seite 112

VTrak M-Class Product ManualiiCopyright© 2006 Promise Technology, Inc. All Rights Reserved.Copyright by Promise Technology, Inc. (Promise Technology).

Seite 113

VTrak M-Class Product Manual12Mount VTrak M500f/i/p in a RackFigure 1. Rackmounted VTrak M500f/i/pThe VTrak M500f/i/p installs directly to the rack wi

Seite 114

VTrak M-Class Product Manual192DHCPIf you enable DHCP, IP Address, Subnet Mask, and Gateway are set automatically.1. Highlight DHCP and press the spac

Seite 115

Chapter 5: Management with the CLU193Port Settings1. Highlight Fibre Channel Port Settings and press Enter.2. Highlight the following parameters and p

Seite 116

VTrak M-Class Product Manual194• Transceiver type• Transceiver code• Manufacturing Date – Year, month, day format• Vendor Name – Vendor name of the SF

Seite 117

Chapter 5: Management with the CLU195iSCSI ManagementiSCSI Management deals with all iSCSI settings and functions with the exception of network connec

Seite 118 - Restore Factory Defaults

VTrak M-Class Product Manual196Port information appears.Port StatisticsTo access port statistics, highlight one of the following and press Enter:• MAC

Seite 119 - Shutdown and Restart

Chapter 5: Management with the CLU197When enabled, you must indicate whether to use a Directory Agent.5. Highlight Use Directory Agent (DA) and press

Seite 120 - Monitor the Restart

VTrak M-Class Product Manual198SCSI ManagementSCSI Management deals with all SCSI settings and functions. This feature appears only with VTrak SCSI mo

Seite 121 - Controllers

Chapter 5: Management with the CLU1993. Type Ctrl-A save your settings.Target Information1. From the Main Menu, highlight SCSI Management and press En

Seite 122

VTrak M-Class Product Manual200Background Activity SettingsUse this feature to make settings for Background Activities. The Activities themselves are

Seite 123

Chapter 5: Management with the CLU201Event ViewerThe Event Viewer displays log of events. Events are classified as Runtime and NVRAM.Runtime EventsThi

Seite 124 - Controller Settings

Chapter 2: Installation13If you plan to use the mounting rails, follow this procedure to install them:1. Attach one end of the rail to the back side o

Seite 125 - Enclosures

VTrak M-Class Product Manual2023. Press the up and down arrow keys to scroll through the log.To clear the NVRAM event log:1. Highlight Clear NVRAM Eve

Seite 126

Chapter 5: Management with the CLU203Dedicated means this spare drive can only be used with the specified disk array(s). Global means this spare drive

Seite 127 - Enclosure

VTrak M-Class Product Manual204LUN Mapping must be enabled in order for VTrak to recognize the initiator. If LUN Mapping is currently disabled, highli

Seite 128

Chapter 5: Management with the CLU2051. From the Main Menu, highlight Additional Info and Management and press Enter.2. Highlight LUN Mapping and pres

Seite 129

VTrak M-Class Product Manual206arrays and logical drives. The default “administrator” account is a Super User. • Power – Allows the user to create (bu

Seite 130 - Physical Drives

Chapter 5: Management with the CLU2073. Highlight Privilege and press the space bar to toggle though the options:• Super – Allows the user full access

Seite 131 - Physical Drives Settings

VTrak M-Class Product Manual208To stop any of these services:1. Highlight the service and press Enter.2. In the Service Setting screen, highlight Stop

Seite 132 - Physical Drive

Chapter 5: Management with the CLU2092. Highlight Startup Type and press the spacebar to toggle between Automatic and Manual.3. Highlight the followin

Seite 133

VTrak M-Class Product Manual210• Read Community – Type a community name in this field• Write Community – private (no change possible)4. Press Ctrl-A t

Seite 134 - Physical Drive Settings

Chapter 5: Management with the CLU211Note: The default name is cim. You cannot change the name or add users.Note: CIM service must be running to chang

Seite 135

VTrak M-Class Product Manual14Mount VTrak M300f/i/p or M200f/i/p in a RackFigure 1. Rackmounted VTrak M300f/i/p (M200f/i/p is similar)The VTrak M300f/

Seite 136 - Disk Arrays

VTrak M-Class Product Manual2123. Highlight Message Event Severity Filter and press the spacebar to change severity levels.4. Press Ctrl-A to save you

Seite 137 - Create a Disk Array – Express

Chapter 5: Management with the CLU213Shutdown and RestartThis function enables you to shutdown or restart the VTrak subsystem. You can only do part of

Seite 138

VTrak M-Class Product Manual2144. Press Y to continue.The screen will go blank.5. Wait for two to three minutes.6. Re-establish your Telnet connection

Seite 139

215Chapter 6: Maintenance• Firmware Update – WebPAM PROe (page 217)• Firmware Update – CLU (page 219)• Replace Power Supply – All Models (page 220)• R

Seite 140 - Delete a Disk Array

VTrak M-Class Product Manual216Figure 2. Field Replaceable Units (FRUs) on VTrak M300f/M200f (M300i/p and M200i/p are similar)The primary means to ide

Seite 141 - Disk Array

Chapter 6: Maintenance217Firmware Update – WebPAM PROeBefore you begin, go to the Promise website www.promise.com and download the latest firmware upd

Seite 142 - Disk Array Status

VTrak M-Class Product Manual2185. Do one of the following: • Click on the Download Flash File from Local File through HTTP option, then click on the N

Seite 143 - Create a Logical Drive

Chapter 6: Maintenance219Firmware Update – CLUUse this function to flash the VTrak’s firmware. Before you begin, go to the Promise website www.promise

Seite 144

VTrak M-Class Product Manual2203. Press the spacebar to display Restart then press Enter.A warning message appears.4. Press Y to continue.The screen w

Seite 145 - Disk Array Migration

Chapter 6: Maintenance221Replace Cooling Unit Fan – M500f/i/pThe blowers (scroll fans) in the cooling units are replaced as individual parts. There ar

Seite 146 - Disk Array Rebuild

Chapter 2: Installation15Follow this procedure to install the rails:1. Check the fit of the rails in your rack system.2. Slide the plates out of the r

Seite 147

VTrak M-Class Product Manual2223. Pull the cooling unit out of the VTrak enclosure. An example of a VTrak cooling unit appears below. To open the cool

Seite 148 - Transition

Chapter 6: Maintenance2235. Loosen the thumbscrew (above). A retainer keeps the thumbscrew in place. 6. Grasp the top and bottom sections of the cooli

Seite 149 - Logical Drives

VTrak M-Class Product Manual2248. Separate the cooling unit section to access the blowers.The upper fan is Fan 1, the lower fan is Fan 2. From the LED

Seite 150 - Logical Drive Status

Chapter 6: Maintenance225Be sure you set the fan on the mounting pins, as shown above.Be sure the fans point outward, towards the handle (above).11. P

Seite 151 - Logical Drive

VTrak M-Class Product Manual226Replace Cooling Unit Fan – M300f/i/p and M200f/i/pThe blowers (scroll fans) in the cooling units are replaced as indivi

Seite 152 - Logical Drive Settings

Chapter 6: Maintenance227 An example of a VTrak cooling unit appears above. 5. Loosen the thumbscrews (above). Retainers keep the thumbscrews in place

Seite 153 - Logical Drive Initialization

VTrak M-Class Product Manual2287. Separate the cooling unit sections to access the blowers.Viewed from the inside (battery) end on the cooling unit, t

Seite 154 - Logical Drive Synchronization

Chapter 6: Maintenance229Be sure the blowers point outward, towards the handle, as shown above.10. Place the top section of the cooling unit onto the

Seite 155 - Logical Drive Check Table

VTrak M-Class Product Manual230Replace Cache Battery – M500f/i/pThe cache battery is located in the Cooling Unit 1 (the left one). The battery is repl

Seite 156

Chapter 6: Maintenance231 2. Press the release button and pull the handle downward as shown above.3. Pull the cooling unit out of the VTrak enclosure.

Seite 157

VTrak M-Class Product Manual16Install Disk Drives You can populate the VTrak with 1.5 GB and 3.0 GB SATA drives.• VTrak M500f/i/p supports up to 15 di

Seite 158 - Spare Drives

VTrak M-Class Product Manual2326. Carefully slide the cooling unit into the enclosure. 7. Gently press the handle in and upward until it locks (abov

Seite 159 - Create Spare Drive

Chapter 6: Maintenance233Replace Cache Battery – M300f/i/p and M200f/i/pThe cache battery is located in the Cooling Unit. The battery is replaced as a

Seite 160 - Delete Spare Drive

VTrak M-Class Product Manual234 5. Detach the connector and lift the battery out of the bracket (above).6. Place a new battery into the bracket and at

Seite 161 - Spare Drive

Chapter 6: Maintenance235Replace SEP – M500f/i/pThe Storage Enclosure Processor (SEP) manages the fans, audible alarm, and battery, and monitors syste

Seite 162 - Spare Drive Settings

VTrak M-Class Product Manual236Replace SEP – M300f/i/p and M200f/i/pThe Storage Enclosure Processor (SEP) manages the fans, audible alarm and battery,

Seite 163 - Logical Drive Summary

Chapter 6: Maintenance237Replace RAID Controller – All ModelsThe RAID Controller monitors and manages the logical drives. When this controller is repl

Seite 164

VTrak M-Class Product Manual238

Seite 165 - VTrak Status Indicators

239Chapter 7: Technology Background• Introduction to RAID (below)• Choosing a RAID Level (page 247)• Stripe Size (page 250)• Sector Size (page 250)• C

Seite 166

VTrak M-Class Product Manual240RAID 0 – StripeWhen a disk array is striped, the read and write blocks of data are interleaved between the sectors of m

Seite 167 - Drive Status Indicators

Chapter 7: Technology Background241RAID 1 – MirrorWhen a disk array is mirrored, identical data is written to a pair of drives, while reads are perfor

Seite 168 - Audible Alarm

Chapter 2: Installation17 Figure 10.M500f/i/p drive carrier mounting holesFigure 11. M300f/i/p and M200f/i/p drive carrier mounting holesWARNING:Count

Seite 169 - CLU Connection

VTrak M-Class Product Manual242RAID 1E – Enhanced MirrorRAID 1E offers the security of mirrored data provided by RAID 1 plus the added capacity of mor

Seite 170

Chapter 7: Technology Background243RAID 5 – Block and Parity StripeRAID 5 organizes block data and parity data across the physical drives. Generally,

Seite 171 - Exit the CLU

VTrak M-Class Product Manual244RAID 10 – Mirror + StripeMirroring/striping combines both of the previous RAID 1 and RAID 0 disk array types. RAID 10 i

Seite 172 - CLU Function Map

Chapter 7: Technology Background245RAID 50 – Striping of Distributed ParityRAID 50 combines both RAID 5 and RAID 0 features. Data is striped across di

Seite 173 - C, continued

VTrak M-Class Product Manual246attempts to distribute the number of disk drives equally among the axles but in some cases, one axle will have more dis

Seite 174 - E, continued

Chapter 7: Technology Background247Choosing a RAID LevelThere are several issues to consider when choosing the RAID Level for your VTrak disk array. T

Seite 175 - I, continued

VTrak M-Class Product Manual248RAID 1ERecommended Applications for RAID 1E• Imaging applications • Database servers • General fileserverRAID 5Recommen

Seite 176 - L, continued

Chapter 7: Technology Background249RAID 50Recommended Applications for RAID 50• File and Application servers • Transaction processing• Office applicat

Seite 177 - P, continued

VTrak M-Class Product Manual250Stripe SizeStripe Size, also called “Stripe Block Size”, refers to the size of the data blocks written to, and read fro

Seite 178

Chapter 7: Technology Background251To make use of logical drives greater than 2TB in size, a larger sector size is required. The table below correlate

Seite 179 - S, continued

VTrak M-Class Product Manual18Figure 12.SATA Disk Drives mount at the front of the carrier1. Carefully lay the drive into the drive carrier at the fro

Seite 180 - U, continued

VTrak M-Class Product Manual252• Read Ahead – The read cache and the read-ahead feature are enabled. Read-ahead anticipates the next read and performs

Seite 181 - Subsystem Management

Chapter 7: Technology Background253Capacity Coercion also affects a replacement drive used in a disk array. Normally, when an physical drive fails, th

Seite 182 - Controller Management

VTrak M-Class Product Manual254The spare drive effectively takes the place of the failed drive and the RAID system immediately begins to rebuild data

Seite 183 - Physical Drive Coercion

Chapter 7: Technology Background255RAID 5 RAID 50 •*RAID 10 •RAID 0 • • •RAID 1/1E RAID 50 • •RAID 10 • •RAID 5 • •RAID 0 • • •RAID 0 RAID 50 • • •RAI

Seite 184 - Enclosure Status

VTrak M-Class Product Manual256Ranges of Disk Array ExpansionThere are limitations to how large you can expand a disk array, depending on the size of

Seite 185 - Enclosure Settings

Chapter 7: Technology Background2572. Delete the current logical drive.See page 137 (WebPAM PROe) or page 188 (CLU).3. Create a new logical drive with

Seite 186 - Batteries

VTrak M-Class Product Manual258A disk drive becomes unhealthy when: • A SMART error is reported • The bad sector remapping table fills to the specifie

Seite 187 - Physical Drive Management

Chapter 7: Technology Background259ExampleFollowing is an example to explain the Transition function.In the example above, there is a four-drive RAID

Seite 188 - Physical Drive Statistics

VTrak M-Class Product Manual260There is no spare drive at this moment. Even if physical drive 5 is of adequate capacity, it has not been designated as

Seite 189 - Locate Physical Drive

261Chapter 8: Troubleshooting• VTrak is Beeping (below)• LEDs Display Amber or Red (page 262)• CLU Reports a Problem (page 268)• WebPAM PROe Reports a

Seite 190 - Disk Array Management

Chapter 2: Installation19Each disk drive in VTrak is identified by a number used for creating and managing logical drives. VTrak numbers disk drives f

Seite 191 - Advanced

VTrak M-Class Product Manual262To make alarm settings or cancel an alarm, see page 121 (WebPAM PROe) or page 214 (CLU).LEDs Display Amber or RedFront

Seite 192

Chapter 8: Troubleshooting263• Fibre Channel/iSCSI/SCSI LEDs flash green if there is activity on that channel. See the table below.See page 215 for mo

Seite 193 - Disk Array Information

VTrak M-Class Product Manual264Drive Status IndicatorsThere are two LEDs on each Drive Carrier. They report the presence of power and a disk drive, an

Seite 194 - Predictive Data Migration

Chapter 8: Troubleshooting265Back of EnclosureWhen the FRU Status LED on VTrak’s front panel shows Amber or Red, check the LEDs on the back of VTrak.

Seite 195 - Locate Disk Array

VTrak M-Class Product Manual266Figure 8. Battery and fan LEDs VTrak M300f/i/p and M200f/i/pUnder normal conditions, the power supply, battery, and fan

Seite 196 - Logical Drive Management

Chapter 8: Troubleshooting267Figure 10.A VTrak iSCSI controllerFigure 11. A VTrak SCSI controllerUnder normal conditions, the Controller Status LED (m

Seite 197 - Logical Drive Information

VTrak M-Class Product Manual268CLU Reports a ProblemThe CLU reports information passively—you must determine which functions to check based on the sou

Seite 198 - Locate Logical Drive

Chapter 8: Troubleshooting269• Highlight Rebuild and press Enter to rebuild the array after you replace the failed disk driveFor more information, see

Seite 199 - Network Management

VTrak M-Class Product Manual270• Keeps a record in the Event Log (above)• Displays full information on the selected component in the Management Window

Seite 200 - Fibre Channel Management

Chapter 8: Troubleshooting271Event Notification ResponseWhen you select Event Notification, WebPAM PROe sends popup and/or email messages regarding it

Seite 201 - Port SFP

VTrak M-Class Product Manual20Set Up Network Cable ConnectionsThe VTrak M500f, M300f, and M200f share the same RAID controller design and use Fibre Ch

Seite 202 - Fibre Channel Initiators

VTrak M-Class Product Manual272Battery is charging Battery is being recharged.Battery reconditioning is completeBattery reconditioning is finished.Bat

Seite 203

Chapter 8: Troubleshooting273Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not turn, replace the blowers. See page 221

Seite 204 - Sessions

VTrak M-Class Product Manual274Drive-interface controller is NOT foundRestart the VTrak. See page 218. If this message appears repeatedly, contact Tec

Seite 205 - Delete a CHAP

Chapter 8: Troubleshooting275Host-interface controller has detected bus resetThe initiator sent a reset command. If this message appears repeatedly, c

Seite 206

VTrak M-Class Product Manual276Host-interface controller settings have changedResult of user action. Normal.Fibre ChannelFibre Channel controller has

Seite 207 - Background Activity

Chapter 8: Troubleshooting277Logical drive initialization is aborted due to an internal error.System resources are low. Reduce system load or restart

Seite 208 - Background Activities List

VTrak M-Class Product Manual278Online capacity expansion has completedNormal.Online capacity expansion has pausedExpansion paused because of user inte

Seite 209 - Event Viewer

Chapter 8: Troubleshooting279Physical disk is marked onlineDisk drive removed from service due to errors. If necessary, try to force the disk online.

Seite 210 - Spare Drive Management

VTrak M-Class Product Manual280A physical disk has encountered PFA conditionA potentially faulty address or bad sector was found. A configured dead ph

Seite 211

Chapter 8: Troubleshooting281PSU fan speed increased. Check the VTrak for overheating. See page 289.PSU fan speed decreased.Temporary overheat conditi

Seite 212 - LUN Mapping (SCSI)

Chapter 2: Installation21• A network switch• A network interface card (NIC) in the PCConnect the VTrak Fibre Channel data ports to your Fibre Channel

Seite 213 - User Management

VTrak M-Class Product Manual282RebuildRebuild is started Result of settings or user action. Normal.Rebuild is completed Normal.Rebuild is paused Rebui

Seite 214 - Password

Chapter 8: Troubleshooting283Redundancy Check task is queuedRedundancy Check has been set manually or by schedule.Redundancy Check task is stopped int

Seite 215

VTrak M-Class Product Manual284Stripe Level MigrationStripe Level migration is startedResult of settings or user action. Normal.Stripe Level migration

Seite 216 - Webserver

Chapter 8: Troubleshooting285Synchronization is queuedSynchronization is already running on another logical drive in the same array.Synchronization is

Seite 217

VTrak M-Class Product Manual286Critical & Offline Disk ArraysA fault-tolerant disk array—RAID 1, 1E, 5, 10, and 50—goes critical when a disk drive

Seite 218 - SNMP Trap Sinks

Chapter 8: Troubleshooting287Without a Hot Spare DriveIf there is no hot spare drive of adequate capacity, you must remove the failed drive and instal

Seite 219 - Netsend Recipients

VTrak M-Class Product Manual288Figure 4. VTrak M500f/i/p disk carrier LEDs Figure 5. VTrak M300f/i/p and M200f/i/p disk carrier LEDs• The drive carrie

Seite 220 - Flash through TFTP

Chapter 8: Troubleshooting289Enclosure ProblemsWebPAM PROe displays yellow !s red Xs in Tree View to identify components that need attention.When

Seite 221

VTrak M-Class Product Manual290OverheatingOverheating is a potentially serious condition because the excessively high temperatures can lead to disk dr

Seite 222 - Restart over Serial

Chapter 8: Troubleshooting291 Power SuppliesVTraks are equipped with redundant power supplies. The advantage of dual power supplies is that, should on

Seite 223

iiiContentsChapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1About This Manual . . . . . . . . . . .

Seite 224

VTrak M-Class Product Manual22iSCSI Storage Area Network Figure 10. VTrak M300i and M200i SAN connections (M500i is similar)This arrangement requires:

Seite 225 - Firmware Update – WebPAM PROe

VTrak M-Class Product Manual292Connection ProblemsWhen you install your Promise product following the instructions in the Quick Start Guide and this P

Seite 226 - Restart VTrak

Chapter 8: Troubleshooting293 This means you can, for example, connect your Host PC to one of the VTrak’s SCSI “In” ports without the need of an exter

Seite 227 - Firmware Update – CLU

VTrak M-Class Product Manual294Network ConnectionsVTrak has an RJ-45 Management Port connector on the back of its cabinet. This is a Gigabit Ethernet

Seite 228

Chapter 8: Troubleshooting295Unsaved Data in the Controller CacheThe VTrak M-Class controller has a 256 MB data memory cache protected by a battery ba

Seite 229 - Chapter 6: Maintenance

VTrak M-Class Product Manual296

Seite 230

297Chapter 9: Support• Frequently Asked Questions (below)• Contact Technical Support (page 299)• Limited Warranty (page 302)• Returning product for re

Seite 231

VTrak M-Class Product Manual298My WebPAM connection was working OK. But later on, it timed out. What do I do now?The network condition can time-out fo

Seite 232

Chapter 9: Support299How can I be sure everything is working OK on the VTrak?Locally: The VTrak enclosure has LEDs on the front to monitor the status

Seite 233

VTrak M-Class Product Manual300United StatesEurope, Africa, Middle East GermanyItalyE-mail Support [email protected] Support (408) 228-1097 Attn

Seite 234

Chapter 9: Support301Taiwan China E-mail Support [email protected] Support +886 3 578 2390 Attn: Technical SupportPhone Support +886 3 578 239

Seite 235

Chapter 2: Installation23iSCSI Direct Attached StorageFigure 11. VTrak M300i and M200i DAS connections (M500i is similar)This arrangement requires:•

Seite 236

VTrak M-Class Product Manual302Limited WarrantyPromise Technology, Inc. (“Promise”) warrants that for three (3) years from the time of the delivery of

Seite 237

Chapter 9: Support303No other document, statement or representation may be relied on to vary the terms of this limited warranty.Promise’s sole respons

Seite 238

VTrak M-Class Product Manual304The technician will assist you in determining whether the product requires repair. If the product needs repair, the Tec

Seite 239

305Appendix A: Useful Information• Serial Connector Pinout (below)• SNMP MIB Files (page 306)Serial Connector PinoutBelow is the pinout diagram for th

Seite 240

VTrak M-Class Product Manual306SNMP MIB FilesPromise supplies seven MIB files to integrate the VTrak M-Class subsystem into your SNMP system. These fi

Seite 241

307IndexAAbout This Manual 1Accept Incomplete Array 187Alias 185Architectural Description of VTrak 3Architectural Description, VTrak M-Class 3Audible

Seite 242

VTrak M-Class Product Manual308DDASFibre Channel 21iSCSI 23SCSI 24Date and Time 174date and time settingCLI 30CLU 32, 35Dead 135, 143Dedicated to Arra

Seite 243 - Replace SEP – M500f/i/p

Index309Events, contuneddisk array 273Drive-interface controller 273Enclosure 274Event logging 274Fibre Channel 276Host-interface controller 274iSCSI

Seite 244

VTrak M-Class Product Manual310Initiator 97create 204delete 204Fibre Channel 87, 194Install disk drives 16iSCSI 93Activity LED 26, 58, 158, 263CHAP 93

Seite 245

Index311LUN mappingFibre Channel 98, 148, 203iSCSI 98, 148, 203SCSI 99, 149, 204MM200f/i/pfront panel LED 26rackmount 14specifications 8M300f 8M300f/i

Seite 246

VTrak M-Class Product Manual24SCSI Direct Attached StorageFigure 12. VTrak M300p and M200p DAS connections (M500p is similar)This arrangement requires

Seite 247 - Introduction to RAID

VTrak M-Class Product Manual312PortFibreChannel 84iSCSI 89power connection 26Power LED 26, 58, 158, 262Power requirements 7, 9Power Supplies 176, 291r

Seite 248 - RAID 0 – Stripe

Index313Sector size 50, 132, 250Serial cable connection 25Serial connectionproblems 293Serial connection problems 293Server’s IP address 298Session, i

Seite 249 - RAID 1 – Mirror

VTrak M-Class Product Manual314Temperature Sensors 177Temperature Thresholds 178Termination, SCSI 96Test Email 77Transceivers, Fibre Channel 86, 193Tr

Seite 250 - RAID 1E – Enhanced Mirror

Chapter 2: Installation25Set Up Serial Cable Connections The RS-232 Serial connection enables the Command Line Interface (CLI) and Command Line Utilit

Seite 251

VTrak M-Class Product Manual26Connect the PowerPlug in the power cords and switch on both power supplies. When the power is switched on, the LEDs on t

Seite 252 - RAID 10 – Mirror + Stripe

Chapter 2: Installation27There are two LEDs on each Drive Carrier. They report the presence of power and a disk drive, and the current condition of th

Seite 253 - RAID 50 Axles

VTrak M-Class Product Manual28

Seite 254

29Chapter 3: Setup• VTrak Setup with CLI or CLU (below)• Install iSCSI Initiator on the Host PC (page 39)• VTrak Setup with WebPAM PROe (page 41)VTrak

Seite 255 - Choosing a RAID Level

VTrak M-Class Product Manual30CLI: Fibre Channel and SCSI Models (M500f/p, M300f/p, M200f/p)1. Type the following string to set the Date and Time, the

Seite 256 - Advantages Disadvantages

Chapter 3: Setup31administrator@cli> net -a mod -t mgmt -s "primaryip=192.168.10.87, primaryipmask=255.255.255.0, gateway=192.168.10.3"In

Seite 257

VTrak M-Class Product ManualivChapter 3: Setup, continuedLog-out of WebPAM PROe . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Internet Conn

Seite 258 - Sector Size

VTrak M-Class Product Manual32CLU: Fibre Channel and SCSI Models (M500f/p, M300f/p, M200f/p)1. At the admin@cli prompt, type menu and press Enter.The

Seite 259 - Cache Policy

Chapter 3: Setup335. Press Ctrl-A to save these settings and move to the Management Port configuration screen.Management PortBy default, DHCP is enabl

Seite 260 - Capacity Coercion

VTrak M-Class Product Manual345. Press Ctrl-A to save these settings and move to the RAID configuration screen.To make Management Port settings manual

Seite 261 - Hot Spare Drive(s)

Chapter 3: Setup35System Date and Time1. Press the arrow keys to highlight System Date.2. Press the backspace key to erase the current date.3. Type th

Seite 262 - RAID Level Migration

VTrak M-Class Product Manual361. Press the arrow keys to highlight DHCP.2. Press the spacebar to toggle to Disabled. The current Management Port setti

Seite 263 - Capacity Performance Add Lose

Chapter 3: Setup37iSCSI Ports By default, DHCP is enabled on VTrak (above). To set iSCSI Port settings manually, or to view the current settings, you

Seite 264 - Expansion Size

VTrak M-Class Product Manual38The current iSCSI Port settings are displayed (above).To make iSCSI Port settings manually:1. Press the arrow keys to hi

Seite 265 - Media Patrol

Chapter 3: Setup39Install iSCSI Initiator on the Host PCThis step applies to the M500i, M300i, and M200i models only.To access the iSCSI data ports, y

Seite 266

VTrak M-Class Product Manual40After the iSCSI Initiator is installed, follow the installation and setup instructions that come with your GbE NIC card.

Seite 267

Chapter 3: Setup41VTrak Setup with WebPAM PROeSet up with WebPAM PROe consists of the following: • Log-in to WebPAM PROe (below)• Language Selection (

Seite 268 - Manual Transition

ContentsvChapter 4: Management with WebPAM PRO, continuedLogical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 269 - Chapter 8: Troubleshooting

VTrak M-Class Product Manual42.3. When the opening screen appears, type administrator in the User Name field, and type password in the Password field.

Seite 270 - LEDs Display Amber or Red

Chapter 3: Setup43 NoteMake a Bookmark (Netscape Navigator) or set a Favorite (Internet Explorer) of the Login Screen so you can access it easily next

Seite 271

VTrak M-Class Product Manual44The first time you log in to WebPAM PROe, there will be no Users except for “administrator”. Unless you created disk arr

Seite 272

Chapter 3: Setup45Create a Disk ArrayClick on the Disk Arrays icon. The Array Configuration menu appears. Since this VTrak is newly activated, there

Seite 273

VTrak M-Class Product Manual46• Logical Drives – The ID number of the logical drive(s), their RAID level, capacity, and stripe size • Spare Drives – T

Seite 274

Chapter 3: Setup47 Follow these steps to create a new disk array.1. Check the boxes to select any one or a combination of: • Redundancy – The array wi

Seite 275

VTrak M-Class Product Manual48• Transaction Log •Other 4. Click the Update button.Or check the Automatic Update box, and updates will occur automatica

Seite 276 - CLU Reports a Problem

Chapter 3: Setup49If you are uncertain about choosing parameters for your disk array, use the Express or Automatic option to create your disk array. T

Seite 277 - WebPAM PROe Reports a Problem

VTrak M-Class Product Manual50 On this screen you will specify your logical drives. Specify one logical drive at a time until the full capacity of the

Seite 278

Chapter 3: Setup5110. Choose a Read Cache policy:• ReadCache• ReadAhead•No Cache11. Choose a Write Cache policy:• WriteThru•WriteBack12. Click the Upd

Seite 279 - Event Notification Response

VTrak M-Class Product ManualviChapter 5: Management with the CLU, continuedDisk Array Settings and Functions . . . . . . . . . . . . . . . . . . . .

Seite 280 - Event Action

VTrak M-Class Product Manual52If you want to change a logical drive setting, click on the logical drive at the bottom of the window. The entry and the

Seite 281

Chapter 3: Setup5313. When you have finished specifying logical drives, click the Next button.

Seite 282

VTrak M-Class Product Manual54The proposed disk array appears with the logical drive(s) you specified.14. If you agree with the proposed disk array an

Seite 283

Chapter 3: Setup55Internet Connection using WebPAM PROeThe above instructions cover connections between VTrak and your company network. It is also pos

Seite 284

VTrak M-Class Product Manual56

Seite 285

57Chapter 4: Management with WebPAM PROeThis chapter describes using embedded WebPAM PROe to monitor and manage your RAID system. This chapter is divi

Seite 286

VTrak M-Class Product Manual58Figure 2. VTrak M300f/i/p and M200f/i/p front panel LED displayWhen boot-up is finished and the VTrak is functioning nor

Seite 287

Chapter 4: Management with WebPAM PROe59See page 215 for more information about field-replaceable components. See page 286 for a discussion of critica

Seite 288

VTrak M-Class Product Manual60Figure 4. VTrak M300f/i/p and M200f/i/p disk carrier LEDsThe VTrak spins up the disk drives sequentially in order to equ

Seite 289

Chapter 4: Management with WebPAM PROe61The audible alarm sounds at other times to inform you that the VTrak needs attention. But the alarm does not s

Seite 290

ContentsviiChapter 5: Management with the CLU, continuedClear Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212R

Seite 291

VTrak M-Class Product Manual62.3. When the opening screen appears, type administrator in the User Name field and type password in the Password field.T

Seite 292

Chapter 4: Management with WebPAM PROe63After sign-in, the WebPAM PROe opening screen appears.Figure 5. WebPAM PROe Opening ScreenThe first time you l

Seite 293

VTrak M-Class Product Manual64Graphic User InterfaceVTrak features a browser-based, graphic user interface. Your Internet browser is the basic compone

Seite 294 - With a Hot Spare Drive

Chapter 4: Management with WebPAM PROe65There are four major parts to the graphic user interface:HeaderLanguage SelectionThe VTrak graphic user interf

Seite 295 - Rebuild Operation

VTrak M-Class Product Manual663. Click View again to hide the Event Frame. Storage NetworkThe VTrak graphic user interface can currently display in St

Seite 296

Chapter 4: Management with WebPAM PROe67Tree ViewBelow are the components of Tree View. The Administrative Tools section is different for the Super Us

Seite 297 - Enclosure Problems

VTrak M-Class Product Manual68Management WindowThe Management Window provides the actual user interface with the VTrak. This window changes depending

Seite 298

Chapter 4: Management with WebPAM PROe69SubsystemVTrak subsystems are identified in the Tree by their Management Port IP address. Click on the Subsyst

Seite 299

VTrak M-Class Product Manual70Subsystem EventsThe Subsystem–Event tab provides information from the event (log) file of a specific subsystem.Events ar

Seite 300 - Connection Problems

Chapter 4: Management with WebPAM PROe714. In the File Download Security Warning box, click the Save button. 5. In the Save As dialog box, navigate to

Seite 301 - Serial Connections

VTrak M-Class Product ManualviiiChapter 8: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261VTrak is Beeping . . . .

Seite 302 - Network Connections

VTrak M-Class Product Manual72• Medium allocates a balance of system resources to the function and data read/write operations. • High allocates more s

Seite 303

Chapter 4: Management with WebPAM PROe733. Click on the Scheduler tab dropdown menu and select an item (see the list above). 4. In the Scheduler dialo

Seite 304

VTrak M-Class Product Manual745. Click the Submit button. LockThe Subsystem–Lock tab displays lock status and enables you to lock or unlock a subsyste

Seite 305 - Chapter 9: Support

Chapter 4: Management with WebPAM PROe755. Click the Submit button. Release LockTo release the lock for this subsystem:1. Click on the Subsystem ico

Seite 306

VTrak M-Class Product Manual76User InformationThe User Management–Information tab lists the user, his/her status, access privileges, display name, and

Seite 307 - Contact Technical Support

Chapter 4: Management with WebPAM PROe771. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools icon. 3. Click on the User Man

Seite 308 - Europe, Africa, Middle East

VTrak M-Class Product Manual78List of User Notification Events•Shortcuts • Enclosure – All items under Enclosure have the same Severity level • RAID C

Seite 309 - Attn: Technical Support

Chapter 4: Management with WebPAM PROe79User Password – AdministratorThe Administrator or a Super User can change another user’s password. To make the

Seite 310 - Limited Warranty

VTrak M-Class Product Manual806. Enter a password for this user in the New Password and Retype Password fields.A password is optional. If you do not a

Seite 311 - Returning Product For Repair

Chapter 4: Management with WebPAM PROe814. Click on the Delete tab in Management View. 5. Check the box to the left of the user you want to delete. 6.

Seite 312

1Chapter 1: Introduction• About This Manual (below)• Overview (page 2)• Architectural Description (page 3)• Specifications (page 6)Thank you for purch

Seite 313 - 1 2 3 4 5

VTrak M-Class Product Manual82Management PortThe Network Management–Ethernet tab enables you to see the current Management Port settings on the Contro

Seite 314 - SNMP MIB Files

Chapter 4: Management with WebPAM PROe83• Controller ID • Maximum number of ports supported • Number of ports present • Number of failed ports • Port

Seite 315

VTrak M-Class Product Manual84• Firmware Version • Number of failed nodes • Supported Features • Maximum Frame Size • Supported Speeds To access this

Seite 316

Chapter 4: Management with WebPAM PROe85• Configured Topology – N-Port (Point-to-Point), NL Port (Arbitrated Loop) or Auto (self-setting) • Hard ALPA

Seite 317

VTrak M-Class Product Manual86• Number of words sent • Number of words received • LIP Count – Loop initialization primitive count • NOS Count – Not op

Seite 318

Chapter 4: Management with WebPAM PROe87To access this tab:1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools icon. 3. Cl

Seite 319

VTrak M-Class Product Manual882. Click the Administrative Tools icon. 3. Click on the Fibre Channel Management icon. 4. Click the Initiator tab in

Seite 320

Chapter 4: Management with WebPAM PROe89• Data sequence in order – Enables placement of data in sequence order. • Uni-directional CHAP Authentication

Seite 321

VTrak M-Class Product Manual90• Primary Header Digest Method – (None). • Primary Data Digest Method – (None). • iSCSI Receive Marker – (None). iSCSI P

Seite 322

Chapter 4: Management with WebPAM PROe91• Transmitted Segments • Transmitted Bytes • Received Segments • Received Bytes • Retransmit Timer Expire • Pe

Kommentare zu diesen Handbüchern

Keine Kommentare