Chapter 4: Management with WebPAM PROe
175
Managing Spare Drives
When a physical drive in a disk array fails and a spare drive of adequate capacity
is available, the disk array will begin to rebuild automatically using the spare
drive. See “Critical & Offline Disk Arrays” on page 394.
Spare drive management includes the following functions:
Viewing a List of Spare Drives (page 175)
Locating a Spare Drive (page 175)
Creating a Spare Drive (page 176)
Deleting Spare Drive (page 177)
Making Spare Drive Settings (page 177)
Running Spare Check (page 178)
Viewing a List of Spare Drives
To view a list of spare drives:
1. Click the Subsystem icon in Tree View.
2. Click the Spare Drives icon.
The information includes:
ID – The unique ID number assigned to the spare drive.
Operational Status – OK is normal. Can also show Rebuilding, Transition
Running, PDM Running, or Offline.
Physical Drive ID – The ID number of the physical drive in the subsystem
enclosure.
Capacity – The data storage capacity of this spare drive.
Revertible – Yes or No. A revertible spare drive automatically returns to its
spare drive assignment after the failed physical drive in the disk array is
replaced.
Type – Global, can be used by any disk array. Dedicated, can only be used
by the assigned disk array.
Dedicated to Array – For dedicated spares, the disk array to which it is
assigned. Global spares show N/A.
Locating a Spare Drive
To locate a physical drive assigned as a spare drive in the VessRAID subsystem
enclosure:
1. Click the Subsystem icon in Tree View.
2. Click the Spare Drives icon.